Irish Fire Services Resource  
...Home | Forums | E-Mail | FAQ | About the Site & Author | Site Map / Search
Emergency? dial 999 or 112......
..Services Organization
Organization Structure
Fire Authorities
Nrth. Ireland Fire Brigade
History of the Service
All Irish Stations
Chief Fire Officers
Airport Fire Service
Auxiliary Fire Service
Retained Services Page
Other Emergency Services
..General Information
The Work of a Firefighter
Employment Information
Fire Statistics
Articles / Reports

Historical Fires

Unions (Conditions etc.)
Publications
..Training / Education
Training (whats involved)
Notes on Tactics , Drills etc
Fire Science Courses
..Dublin Fire Brigade
DFB Pages
..Equipment

Fire Appliance Equipment

Fire Engines
..Other Sections
Photograph Galleries
Young Firefighters
Swaps / Trades
Downloads
Links
F.B. Sports Association
Poetry

Home > Fire Appliance Equipment

Page updated on October 17th 2006
The following is a list of equipment which is carried on a standard fire appliance in Ireland. In general the equipment is the same but obviously some equipment and the layout will vary from stations to station and brigade to brigade. Dublin Fire Brigade has a standard equipment layout where each locker on each fire engine in any station will contain almost identical equipment which is useful for easy location in multi pump incidents and also easy to remember for personel when on transfer to a different station.

Rear Pump Locker and roof of Appliance
13.5 metre 3 section aluminum main ladder,
10.5 metre aluminum 2 section main ladder,
5.1 metre folding aluminum roof ladder,
4.5 metre 2 section short extension ladder,

Breathing apparatus tally board,
4 suction spanners,
Foam induction tube,
4 Lengths of 2.44metre hard suction,
4 shovels,
1 wrecking steel bar about 1700mm long,
1 ceiling hook,
2 flaked lengths of 45 mm hose with a spray branch.


Enlarge


1 county type standpipe,
1ball valve type standpipe,
1 standard lugtype standpipe
2 key and bars for opening hydrants and turning on water,
1water key,
Various size false spindles for hydrant valves,
1 foam making branch (450 Litres Minute),
1 foam solution inductor to pick up foam from a container,
1 9 litre maip fire extinguisher,
1 9 Litre drypower fire extinguishers,
2 Carbon dioxide fire extinguishers,
1 portable water pump to obtain water from rivers etc that the main fire engine cannot get down to,
1 dividing breeching for splitting one line of large hose into two,
1 collector head for the portable pump to connect main hose supplying water to it,
10 Litre drum of petrol for the portable pump,
Earthing cable and insulating poles for the Luas light rail system (only in Dublin)


Enlarge

2 disposable gas tight suits
Selection of ropes including a lowering line with two loops at one end.
1x 50 metre dropline which crews carry into a high building and drop out the window to hoist up hose etc.
2x 20 metre floating throwlines and bags for water rescue,
Breathing apparatus guideline tags and tabard for officer,
2 x 60 metre breathin apparatus guidelines
Box containing hand axes, landing wheel valves (water supply in high rise) ship to shore hose connection, lift keys, gas keys, various hose connections.
4 x 45mm dia hose 25 metres long,
1 bucket and shovel for chimney fires,
1x 6 metre length of 100mm hose for ships and large mains,

Enlarge

2 x 55 metre first aid hose reels attached to engine.
1 x  Stirrup pump for chimney fires
2  x  Sets of Chimney rods,
Salvage sheets for protecting peoples carpets!
Set of wooden cribbing blocks for stabilizing cars in road traffic accidents,
2 large high reflective road traffic accident signs,
4 rubber hose ramps to allow cars to drive over hose,
Suction basket and strainer to sieve water going into the pump from a river etc.
2 Drums of Alcoseal 3-6% Low expansion foam


Enlarge

1 x  Large felling axe.
5  x  Small hand axes.
1  x  Sledgehammer.
1  x  Crowbar.
1  x  Door persuader.
2 x bolt cutters,
1 x large angle grinder con saw petrol driven,
1 x battery operated reciprocating saw
Tool box
2 sets of electrical gloves
Glass management kit for vehicle windscreen including Glassmaster© saw and soft patient protection,
2 x teardrops. Hard plastic protection for patients while in a vehicle being cut up.
A Holmatro pump with 2 tool outlets (720 bar operating pressure)
1 x cutters,
1 x spreaders,
1 x large ram,
1 vehilce sill support for use primarily with the holmatro ram.


Enlarge

Set of insulated poles and earthing cable equipment for use on the Luas light rail overhead cables in Dublin,
4 blue flashing beacons for road accidents,
1 drag for pulling out rubbish from fires,
1 large yard sweeping brush,
2 gorse beaters (long poles with flexible rubber mat on one end)
10 lengths of 70mm dia. 25 metre large hose,
3 water branches all with spray diffuser pattern and 0.3mm droplet making capability.
2 hose becketts / slings to carry the weight of vertically suspended hose,


Enlarge

1 Manual back up hydraulic pump for extrication equipment,
2 Airbag protection devices to prevent late airbag deployment on a rescuer / casualty,
Set of collapsible road traffic cones,
Searchlight on 90 metre reel,
2x 20 tonne lighting capacity airbags and control unit.
Warning tape,
Spray can for vehicle position marking,
2 Drums of Alcoseal 3-6% Low expansion foam

Enlarge

Other items carried
First Aid Items

Physiocontrol 500 defibrillator
1  x  Set of 6 Stiff Neck immobilization collars.
1  x  Small oxygen.
Dressings.
Water Gel for burns.
Sphygmomanometer (blood pressure cuff and gauge).
Stethoscope.
Selection of oxygen masks and airways.
Blankets.
Adult and paediatric bag valve mask.

Miscellaneous
2 drysuits , buoyancy aids and associated equipment for Swiftwater rescue operations.
2 Sets of waders for flooding,
6 Lifejackets,
Hazardous chemicals reference books,
Gas detection unit,
Hand radios,
Intrinsically safe torches.


Related Pages